Metric bolt torque chart.

Guide torque values for metric coarse bolts, by size, property class and thread condition. An M12 class 8.8 bolt needs about 88 N·m dry (K = 0.20) and about 57 N·m lubricated (K = 0.13) for the same 36,7 kN preload. These are calculated guide values, not a joint design.

Geprüft am 11. Nov. 2026 · Grundlage: ISO 898-1:2013 (proof stress, stress area); T = K · F · d with F = 75% of proof load; typical nut factors K · Fehler melden

Druckbare Tabelle herunterladen (PDF, Englisch)

Fragen dazu?

How the values are calculated.

T = K × F × d. Preload F is 75% of the proof load: proof stress Sp from ISO 898-1 times the tensile stress area As. K is the nut factor, which depends on the finish and lubrication; the values below are typical, and real friction varies widely. For a calculated joint, use VDI 2230 or the fastener supplier's tested values; the value specified by the equipment maker or designer always governs.

Calculate other preloads or sizes with the torque calculator

Guide torque (N·m), Plain or black, dry; Zinc plated, dry, K = 0.2
SizeClass 8.8Class 10.9Class 12.9Class 8.8 (ft·lbf)
M61115188
M825364319
M1050728437
M128812614765
M14141201235104
M16218312365161
M18312431504230
M20441610712325
M22601831971443
M247611.0531.231562
M271.1161.5441.805823
M301.5142.0942.4471.116
M362.6463.6614.2781.952
Quelle: Calculated: T = 0.2 × F × d, F = 0.75 × Sp × As (ISO 898-1). Guide values only.
Guide torque (N·m), Hot-dip galvanized, K = 0.25
SizeClass 8.8Class 10.9Class 12.9Class 8.8 (ft·lbf)
M613192210
M832465323
M10639010547
M1211015718481
M14176252294130
M16273390456201
M18390539630287
M20551762890406
M227511.0391.214554
M249521.3171.539702
M271.3951.9302.2561.029
M301.8922.6173.0591.396
M363.3084.5765.3472.440
Quelle: Calculated: T = 0.25 × F × d, F = 0.75 × Sp × As (ISO 898-1). Guide values only.
Guide torque (N·m), Lightly oiled, K = 0.18
SizeClass 8.8Class 10.9Class 12.9Class 8.8 (ft·lbf)
M6914167
M823333817
M1045657633
M127911313258
M1412718121293
M16196281328145
M18281388454207
M20397549641293
M22541748874399
M246859481.108505
M271.0051.3901.624741
M301.3621.8842.2021.005
M362.3823.2943.8501.757
Quelle: Calculated: T = 0.18 × F × d, F = 0.75 × Sp × As (ISO 898-1). Guide values only.
Guide torque (N·m), Lubricated (MoS₂ paste or wax), K = 0.13
SizeClass 8.8Class 10.9Class 12.9Class 8.8 (ft·lbf)
M6710115
M817242812
M1033475524
M1257829642
M149113115367
M16142203237105
M18203280328149
M20286396463211
M22390540631288
M24495685800365
M277261.0041.173535
M309841.3611.591726
M361.7202.3792.7811.269
Quelle: Calculated: T = 0.13 × F × d, F = 0.75 × Sp × As (ISO 898-1). Guide values only.
Preload at 75% of proof load (kN), all finishes
SizeStress area As (mm²)Class 8.8Class 10.9Class 12.9
M620,18,812,514,6
M836,615,922,826,6
M1058,025,236,142,2
M1284,336,752,561,3
M14115,450,271,984,0
M16156,768,297,5114,0
M18192,586,6119,8140,0
M20244,8110,2152,4178,1
M22303,4136,5188,9220,7
M24352,5158,6219,4256,4
M27459,4206,7286,0334,2
M30560,6252,3349,0407,8
M36816,7367,5508,4594,2
Quelle: Calculated: F = 0.75 × Sp × As; Sp and the As formula from ISO 898-1:2013. Class 8.8 uses Sp 580 MPa up to M16 and 600 MPa above.

Referenzwerte, keine Auslegung.

Die Werte sind Nennwerte der genannten Normen oder, wo gekennzeichnet, daraus berechnet. Maßgeblich sind immer die gültige Norm und Ihre Zeichnung.

Alle Tools

Häufige Fragen von Einkäufern.

What is the torque for an M12 8.8 bolt?

About 88 N·m for a dry plain or zinc-plated thread (K = 0.20), giving about 36,7 kN preload at 75% of proof load. Lubricated with MoS₂ paste or wax (K = 0.13), about 57 N·m gives the same preload. Follow the value your designer or equipment maker specifies.

Why are there different torque values for the same bolt?

Most tightening torque is lost to friction under the head and in the thread. The nut factor K captures that friction, so a lubricated bolt reaches the same preload at a lower torque. Using a dry value on a lubricated bolt can overstretch or break it.

Do stainless A2 and A4 bolts use this chart?

No. This chart uses the proof stresses of ISO 898-1 for carbon and alloy steel classes 8.8, 10.9 and 12.9. Stainless bolts to ISO 3506-1 have different strength values and are prone to galling, so use the supplier's torque values for them.

Senden Sie uns Ihre Zeichnung. Wir antworten innerhalb eines Werktags.